Deye SUN-SMART-SWITCH01P3 Smart Switch
- Connection: Single-phase or three-phase
- Voltage range: 94–238V AC phase voltage
- Maximum phase current: 25A
- Communication: LoRa
Controlled switching for supported single- or three-phase loads
Deye SUN-SMART-SWITCH01P3 is a LoRa smart switch for the compatible Deye energy-management system. It supports single- or three-phase connections, with a listed 94–238V AC phase-voltage range and maximum phase current of 25A.

Coordinate discretionary loads with the energy strategy
The manufacturer describes smart control of higher-power loads through the Deye ecosystem. The IP65 unit weighs 0.4kg. Select loads using their actual running and startup characteristics and the device’s permitted switching duty; the communication feature does not increase its electrical current rating.
Smart control for a supported load arrangement
SUN-SMART-SWITCH01P3 supports the listed single-phase or three-phase connection arrangement, LoRa communication and a maximum phase current of 25A. These characteristics give the installer defined limits for a supported control application. The smart switch belongs within the chosen Deye control architecture, with its duty matched to the connected load.

Key details that shape the system design
Connect the intended equipment
Communication: LoRa
The documented interface identifies how this component communicates with the wider system. The host model, supported protocol and commissioning settings still matter; a matching connector or shared brand name is only part of the check.
Choose a suitable equipment location
Protection: IP65
Consider the enclosure rating together with the manufacturer’s environmental and mounting instructions. Cable entries, ventilation, service access and exposure at the intended position all form part of the installation design.
Designed around the way your system works
A specific role in the energy-management system
Energy-management accessories perform distinct measurement, communication or control tasks. Selecting the correct component starts with identifying that task and the host equipment it must work with. A shared brand name or similar enclosure is not enough to establish compatibility.
Use the exact product reference and the manufacturer’s architecture when choosing the accessory. Where another transmitter, receiver, controller or inverter interface is required, it forms part of the complete configuration even if it is listed as a separate product.
Make the data useful to the system
A measurement or communication device is valuable when its information reaches the correct control point and is interpreted properly. Phase assignment, direction of measurement, addressing and the selected protocol can all affect the result, depending on the product.
Commissioning should verify the expected readings or control behaviour against the actual installation. A device appearing online does not by itself confirm that every measurement or switching function is configured correctly. The product manual provides the model-specific procedure.

Plan placement and connectivity together
Check the power supply, supported interfaces and installation environment before deciding where the accessory belongs. Radio or network connectivity can be affected by distance, metal enclosures and the building layout. Keep the manufacturer’s placement requirements in view during the design.
For a retrofit, identify the installed inverter or controller model and firmware before ordering. The correct accessory can support an existing energy-management strategy, but it should not be assumed to add an unsupported feature to every system.
Keep the installation records clear
Retain the accessory reference, serial number, connection details and commissioning notes with the system records. These make it easier to diagnose a changed reading or replace the right component later.
Where the accessory interfaces with electrical distribution or battery equipment, configuration and connection work should be completed by qualified personnel. The product description explains its role; the manufacturer manual remains the reference for the installation procedure.

Where this product fits
New energy-management installations
Select the accessory for its stated measurement, communication or control role and the exact host equipment.
Supported system upgrades
Check installed equipment and firmware before adding a new interface or control component.
Commissioning and maintenance
Use documented readings and connection details to confirm correct operation and support future servicing.
SUN-SMART-SWITCH01P3 technical specifications
| Manufacturer model | SUN-SMART-SWITCH01P3 |
|---|---|
| Connection | Single-phase or three-phase |
| Voltage range | 94–238V AC phase voltage |
| Maximum phase current | 25A |
| Communication | LoRa |
| Protection | IP65 |
| Weight | 0.4kg |
Product documents & downloads
Your questions about SUN-SMART-SWITCH01P3
Which exact version does this page describe?
This page is for SUN-SMART-SWITCH01P3. Use that complete reference when checking the host equipment, connections and documented operating limits; a similar product name does not establish that two versions have the same function.
Is this a complete solar and battery system?
This listing covers SUN-SMART-SWITCH01P3 and its specified function. The surrounding equipment and installation arrangement must be selected for the complete application.
What information helps Solar Deity recommend a suitable configuration?
Send the SUN-SMART-SWITCH01P3 reference together with your existing equipment models, intended application and host equipment, interface and connectivity requirements. Those details make the discussion more useful than a headline power or capacity figure alone.
Which document should I use for installation?
Use the applicable manufacturer installation or user manual for the exact model and hardware revision. The specification document in the download section supports product selection; a shared family document may cover several variants. Keep the selected model column and the equipment nameplate aligned when preparing the installation.
Plan your next step with Solar Deity
Bring together the right equipment interface and monitoring arrangement for your property. Share the SUN-SMART-SWITCH01P3 reference and your requirements so our team can help you evaluate a suitable configuration.
Discuss your system




