Pylontech A2000-OMNI: 2,069.76kWh container storage
- 2,069.76kWh reference battery energy
- 2 × 500kW conversion reference
- Confirm 50Hz configuration for South Africa

Customized C&I solution — price on request. Estimated lead time: approximately 90 days, subject to confirmation of the final configuration and delivery schedule.
A2000-OMNI — system overview
A2000-OMNI is a 20-foot-format, air-cooled storage system for commercial and industrial projects. The reference battery capacity is 2,069.76kWh. The published reference arrangement uses two 500kW PCS units; lower-power and reduced-energy configurations are also shown in the portfolio.

Configuration and integration
The family range spans approximately 1,207–2,070kWh and 250–1,000kW. Its reference battery voltage is 638–781V DC, with 98% depth of discharge stated for a single string. The container measures 6,058 × 2,438 × 2,896mm and has a published weight of 28 tonnes.
Application and project planning
This platform can support scheduled energy shifting and solar self-consumption at sites with a substantial daily load. The selected PCS quantity, point-of-connection voltage and protection arrangement should be stated in the project design. Cooling and auxiliary consumption also need to be included in operating-energy calculations.
Configuration notes
The configuration diagram references 50/60Hz, but the detailed PCS table lists 60Hz ±2.5. A South African 50Hz version must therefore be confirmed before procurement; this listing does not assume every published configuration is locally interchangeable.
Choosing and integrating Pylontech A2000-OMNI
Container storage for larger commercial demand profiles
A2000-OMNI provides a 2,069.76kWh reference battery capacity and a two-by-500kW conversion arrangement in the published material. It can be assessed for projects that have moved beyond cabinet-scale energy requirements. Food processing, manufacturing and other energy-intensive sites should define the size and duration of the demand to be covered before using the headline capacity as the basis of a purchase decision.
Confirm the regional electrical configuration
The reference documents contain a frequency discrepancy: one table states 60Hz, while a diagram indicates 50/60Hz. A South African proposal must confirm the correct 50Hz equipment and applicable connection requirements for the supplied revision. This is a configuration question to resolve during procurement, not something that can be assumed from the family name or a generic compatibility statement.
Separate capacity planning from continuity planning
A large energy store does not on its own determine how production will continue during an outage. The design needs to identify essential processes, switching arrangements, allowable interruption and charging opportunities. It should also state how metering and controls coordinate the conversion units. For a process facility, provide operating schedules and any significant starting loads alongside the demand data so the quotation reflects actual operations.
Where A2000-OMNI fits in the energy system
The completed installation coordinates storage, power conversion and site distribution. The division between integrated equipment and external components depends on the selected model and project configuration.

Technical reference
Technical data
| General Data | |
|---|---|
| Cooling System | Air Cooling |
| Cooling system consumption (kW, Cooling/Heating) | 40 |
| Aux. Power Consumption (kW, continuous/peak, incl. HVAC) | 30 |
| Anti-corrosion | C3H (C5 Optional) |
| Dimension (W*D*H mm,w/o inverter) | 6058*2438*2896 |
| Weight (tons) | 28 |
| Working Temperature Range (℃) | -20~50* |
| Protection Class | IP55 |
| Altitude (m) | ≤4000 |
| Humidity | 5%~95% |
| Fire extinguishing | Perfluoro |
Technical data
| Battery Data | |
|---|---|
| System Capacity (kWh) | 2069.76 |
| Depth of Discharge | 98% (single string) |
| Life Cycle | >7000 |
| DC Voltage Range (Vdc) | 638~781 (single string) |
Technical data
| PCS DC/AC Data On-grid Mode | |
|---|---|
| PCS number | 2 |
| Rated AC Power (kW) | 500 |
| Rated AC Output Voltage (Vac) | 400±15% |
| Rated AC Output Frequency (Hz) | 60±2.5 |
| Max AC Current (A) | 0~720 |
| Overload Capacity | 125%~150%@200ms |
| AC PF | 0.8~1 leading or lagging |
| CEC Efficiency | 97% |
| Isolation Type | Non isolated type |
Technical data
| Operation Mode | |
|---|---|
| Communication Type | RS485 / CAN / Ethernet |
| Operation Logic | Peak Shaving/Energy Shifting/Self-Consumption |
Project scope and delivery
Send Solar Deity your load profile, required backup duration, PV capacity, site location and connection requirements. The quotation will define the selected equipment, control interfaces and commissioning scope. Civil works, transport, external switchgear, transformers and installation are included only where expressly listed in the project quotation. The approximately 90-day lead time is a planning estimate rather than a stocked-item dispatch promise.
Manufacturer documentation
Pylontech official product reference
Reference figures apply to the documented configuration and manufacturer test conditions. Confirm the final model revision and applicable regional approvals before procurement.
Monitoring and operational planning
For a A2000-OMNI project, define which site measurements, battery status information and alarms are required, who can access them, and how the chosen controls communicate. Gateways, software, network access and remote support should be stated in the quotation rather than assumed.

Pylontech A2000-OMNI datasheet and document downloads
Choose the relevant manufacturer document below. Each PDF is hosted on Solar Deity; the language and file size are shown before you open it.
Pylontech A2000-OMNI: frequently asked questions
Is A2000-OMNI rated at exactly 2MWh?
The detailed reference value is 2,069.76kWh. The 2MWh description identifies the broad energy class.
Is a 50Hz South African configuration already confirmed?
No. The published frequency information needs confirmation for the supplied equipment. The project quotation should explicitly state the approved regional configuration.
Do two 500kW units guarantee redundancy?
Not by themselves. Redundancy depends on the controls, electrical architecture, failure modes and loads being served. It should be a stated design requirement rather than an assumption from the number of conversion units.
Which communications are listed?
The reference lists RS485, CAN and Ethernet. The exact protocols, equipment interfaces, gateways and owner access should be defined in the integration scope.
Where can I get the A2000-OMNI datasheet?
Use the document download cards above to open the matched PDF. Check the model, language and revision against the equipment being specified.
Compare the separate Pylontech A1000-OMNI reference — model scope and compatibility differ.
Request a project quotation for A2000-OMNI
Share your site requirements and the exact product configuration you are considering. Our C&I enquiry form accepts business details, electricity usage and project requirements.