Pylontech A100-HY-PLUS: 50kW/108kWh or 60kW/126kWh hybrid ESS
- 50kW/108kWh configuration
- 60kW/126kWh configuration
- Four MPPTs; 100kW PV reference

Customized C&I solution — price on request. Estimated lead time: approximately 90 days, subject to confirmation of the final configuration and delivery schedule.
A100-HY-PLUS — system overview
A100-HY-PLUS integrates a hybrid inverter with an air-cooled LFP battery system. Pylontech documents two matched variants: 50kW with 108kWh, and 60kW with 126kWh. These paired ratings are kept together when preparing a quotation.

Configuration and integration
The platform uses six battery modules and a 302.4–388.8V battery range. Four MPPT trackers, a 150–950V MPPT range and a listed 100kW maximum PV input support a directly connected solar design. The source gives on/off-grid switching below 20ms and 380/400V three-phase output.
Application and project planning
For a factory office, retail building or smaller commercial site, this integrated format can simplify the relationship between solar input and storage. The 50kW and 60kW options differ in battery energy and weight. Array design still requires checks on each string and inverter input rather than relying only on the 100kW PV headline.
Configuration notes
The web table lists 80A maximum AC output current across the family; confirm the exact current limit for the 60kW version. The quotation will specify the selected variant, PV configuration and applicable certification evidence.
Choosing and integrating Pylontech A100-HY-PLUS
Two clearly defined hybrid configurations
A100-HY-PLUS is offered in the reference document as 50kW/108kWh and 60kW/126kWh combinations. Each pairing connects a conversion-power class with a particular storage capacity. A small hotel, office or commercial facility should compare the selected pairing against daily demand, evening consumption and essential loads, rather than combining the largest number from each row of the datasheet into an unsupported configuration.
Make the solar input design part of the specification
The reference lists four MPPTs and a 100kW PV figure. That headline alone is not a solar-string design. Module open-circuit voltage, operating voltage, current, temperature behaviour and the permitted input arrangement must be checked against the exact inverter configuration. Roof orientation and shading also affect how the array is divided across trackers and how much useful charging energy reaches the system.
Check the AC details for the selected version
A generic AC-current value in a family document should not be applied to both power variants without verification. The final offer should confirm the output rating and electrical interface of the actual unit. This is also the point to define reserve settings, essential-load switching, monitoring equipment and any export restriction. Those decisions turn a product comparison into a practical installation proposal.
Where A100-HY-PLUS fits in the energy system
The completed installation coordinates storage, power conversion and site distribution. The division between integrated equipment and external components depends on the selected model and project configuration.

Technical reference
Technical data
| General Data | |
|---|---|
| Dimension (W*D*H mm) | 1050*1300*2100 |
| Weight (Tons) | 1.495/1.620 |
| Working Temperature Range (℃) | -25~50 |
| Protection Class | IP55 |
| Altitude(m) | ≤3000 |
| Humidity | 0~95%RH |
| Fire Extinguishing | Aerosol |
| Cooling System | Air Cooling |
| Cooling System Consumption(kW, Cooling / Heating) | 2 |
| Anti-Corrosion | C3H |
| Battery Data | |
| Battery Type | Li-ion (LFP) |
| Nominal Capacity (kWh) | 108/126 |
| Battery Module Qty. | 6 |
| DC Voltage Range(V) | 302.4 ~ 388.8 |
| Max. Operation Current (A) | 160 |
| Cooling Type | Forced air cooling |
| AC Side Parameters | |
| Rated AC Power (KW ) | 50/60 |
| Rated AC Output Voltage(V) | 380/400Vac,3W+N+PE |
| Rated AC Output Frequency (Hz) | 50/60 |
| Max. AC Output Current(A) | 80 |
| Max. DC Input Current(A) | 100*2 |
| Power Factor | -0.8~0.8 |
| Overload Capacity | 110% @30s |
| ON -Off Grid Switching | <20ms |
| MPPT Parameters | |
| Number of MPPT | 4 |
| Max DC Input Power(kW) | 100 |
| MPPT Voltage Range(V) | 150~950 |
| MPPT Starting voltage(V) | 125 |
| Max DC Input Current(A)/string | 8*20 |
Project scope and delivery
Send Solar Deity your load profile, required backup duration, PV capacity, site location and connection requirements. The quotation will define the selected equipment, control interfaces and commissioning scope. Civil works, transport, external switchgear, transformers and installation are included only where expressly listed in the project quotation. The approximately 90-day lead time is a planning estimate rather than a stocked-item dispatch promise.
Manufacturer documentation
Pylontech official product reference
Reference figures apply to the documented configuration and manufacturer test conditions. Confirm the final model revision and applicable regional approvals before procurement.
Monitoring and operational planning
For a A100-HY-PLUS project, define which site measurements, battery status information and alarms are required, who can access them, and how the chosen controls communicate. Gateways, software, network access and remote support should be stated in the quotation rather than assumed.

Pylontech A100-HY-PLUS datasheet and document downloads
Choose the relevant manufacturer document below. Each PDF is hosted on Solar Deity; the language and file size are shown before you open it.
Pylontech A100-HY-PLUS: frequently asked questions
Is this simply a renamed A100-HY?
No. A100-HY-PLUS has its own documented capacity and power combinations. Use its specific datasheet rather than carrying over the 104kWh reference from the earlier A100-HY family.
Which version is best for a hotel or office?
Compare the required peak power and energy consumption over the intended discharge period. The 60kW version is not automatically preferable if the site mainly needs a different duration or integration arrangement.
Can I connect any 100kW solar array?
No. The array must also satisfy the exact voltage, current and tracker limits. A PV power headline does not establish that an arbitrary string arrangement is acceptable.
Does the page promise built-in Wi-Fi monitoring?
No. Monitoring interfaces, gateways, network access and software availability must be confirmed for the supplied system. The monitoring illustration describes a project concept rather than an included Wi-Fi feature.
Where can I get the A100-HY-PLUS datasheet?
Use the document download cards above to open the matched PDF. Check the model, language and revision against the equipment being specified.
Compare the separate Pylontech A100-HY reference — model scope and compatibility differ.
Request a project quotation for A100-HY-PLUS
Share your site requirements and the exact product configuration you are considering. Our C&I enquiry form accepts business details, electricity usage and project requirements.