Sungrow ST225kWh-110kW-2h: specifications and project guide
Sungrow ST225kWh-110kW-2h is offered by Solar Deity as a customized energy storage solution for South African commercial, industrial and larger energy projects. 229kWh · 110kW.
Cabinet-format storage for commercial facilities
The South Africa-specific ST225kWh-110kW-2h datasheet lists 229kWh nominal battery capacity and 110kW nominal on-grid power at 400V, 50Hz. The ST225 model name is retained for identification, while the technical table uses the published 229kWh value. The source is marked preliminary, so the approved delivery revision must be confirmed before ordering.

What makes this configuration different
Off-grid operation requires an additional transformer cabinet according to the supplied document. Transfer performance and parallel operation must be checked against the complete approved system; the storage cabinet alone should not be presented as a complete plug-and-play backup installation.
Customized solution · Price on request
Indicative lead time is approximately 90 days, subject to final technical scope, manufacturer availability, commercial agreement and order confirmation. This is a planning estimate, not a guaranteed delivery or commissioning date. We quote the equipment and project services against an agreed scope; accessories and site works are not assumed to be included.

Applications to evaluate for your site
Manufacturing facilities, distribution centres and other commercial premises can evaluate storage for solar self-consumption, scheduled energy shifting and peak-demand management. Each use case has a different dispatch pattern: a short demand peak may require substantial power but limited energy, whereas an evening operating shift can need sustained energy delivery. Savings and system size must be assessed from measured consumption, tariffs, solar generation and operating constraints rather than a generic payback claim.
From nominal capacity to a working energy strategy
Nominal battery capacity is a reference value, not the energy guaranteed at the facility meter. Usable state-of-charge limits, conversion losses, auxiliary consumption, temperature, ageing and the agreed reserve reduce or alter the energy available for a particular duty. Likewise, kVA describes apparent power and is not automatically interchangeable with kW. A practical design specifies both the required active-power profile and the usable energy needed throughout the operating window.

Sungrow ST225kWh-110kW-2h technical specifications
The table below follows the supplied manufacturer document for this exact model. Figures are not transferred between product generations. Confirm the currently supplied revision and all optional equipment in the approved quotation.
| Specification | Datasheet value |
|---|---|
| Product name | ST225kWh-110kW-2h |
| Datasheet status | Preliminary; South Africa-specific |
| Cell chemistry | LFP |
| Battery configuration | 256S1P |
| Nominal capacity | 229kWh |
| Nominal DC voltage range | 691.2-934.4V |
| Nominal on-grid power | 110kW |
| Nominal AC voltage | 400V |
| AC voltage range | 340-440V |
| Nominal frequency | 50Hz |
| Current THD | <3% at nominal power |
| Dimensions (W × H × D) | 1,150 × 2,450 × 1,610mm |
| Weight | ≤3,100kg |
| Protection / corrosion | IP55 / C3 default, C5 optional |
| Operating temperature | -30°C to 50°C; derating above 45°C |
| Maximum altitude | ≤3,000m |
| Temperature control | Intelligent liquid cooling |
| Noise | ≤70dB |
| Communication | Ethernet / Modbus TCP |
| Maximum off-grid parallel quantity | ≤10 |
| Standards | IEC 62619, IEC 63056, IEC 62040, IEC 62477, IEC 61000, UN 38.3, NRS 097-2-1 |
Cooling, safety and responsible installation
The referenced battery platform uses liquid cooling to manage battery temperature. The overall installation still needs the manufacturer’s ventilation and access provisions, suitable foundations, drainage, environmental assessment and a site-specific fire and emergency-response plan. Protection and detection features do not remove the need for professional installation or local approvals. Optional fire-safety equipment and corrosion packages must be explicitly identified rather than assumed to be supplied.
Monitoring, communications and operating visibility
The South Africa-specific datasheet lists Ethernet and Modbus TCP, and describes iSolarCloud app or web monitoring. Confirm the supplied gateway, connectivity requirements, access permissions and current service availability during design. Do not assume every illustrated screen, network device or wireless feature is a standard included accessory. Alarm handling, data ownership and remote-access responsibilities should be documented before commissioning.

Information we need to prepare a useful quotation
Send the project location, electricity bills or interval-load data, existing solar and generator details, connection voltage and target commissioning date. Identify essential loads, operating hours, expansion plans and any restrictions on export or network access. For an existing installation, include available single-line diagrams and equipment model numbers. This information allows the proposal to distinguish the required equipment from optional services and site-specific works.
Agree the delivery scope before ordering
- Approved model, source revision, ratings and selected options.
- Plant layout, access, foundations, cable routes and environmental conditions.
- Protection, earthing, grid interface and project approvals.
- Control-system interfaces, metering, commissioning tests and acceptance criteria.
- Transport, unloading, installation responsibilities, training and warranty documentation.
Delivery, commissioning and handover
The approximately 90-day lead time is an indicative procurement assumption. Transport arrangements, site readiness, lifting access, approvals and commissioning resources can affect the final programme. Ask for an agreed delivery milestone and a separate commissioning plan. Handover should include the approved documentation, operating settings, test records, maintenance responsibilities and applicable warranty terms for the supplied configuration.
Sungrow ST225kWh-110kW-2h: frequently asked questions
What does the ST225kWh-110kW-2h model name mean?
Off-grid operation requires an additional transformer cabinet according to the supplied document. Transfer performance and parallel operation must be checked against the complete approved system; the storage cabinet alone should not be presented as a complete plug-and-play backup installation.
Will this system automatically keep my site running during an outage?
Not from the product designation alone. Islanding, transfer controls, protection, essential-load segregation and any additional equipment must be engineered and approved. This source explicitly requires an additional transformer cabinet for off-grid mode.
Are the illustrations an actual installation or complete bill of materials?
No. The manufacturer reference helps identify the product family; generated scenes and monitoring graphics explain possible project contexts. They do not define supplied accessories, exact site spacing, cabinet quantities or the final electrical design.
Is the 90-day lead time guaranteed?
No. It is an indicative planning estimate. Confirm the approved technical scope, manufacturer availability, delivery terms and programme in the quotation.
Which documents should the installer use?
Use the approved model-specific datasheet, installation and commissioning manuals, project drawings and current manufacturer instructions. The downloadable document below is a datasheet, not an installation manual. Request the applicable manuals for the supplied revision before installation.
Sungrow ST225kWh-110kW-2h Datasheet Download
Sungrow ST225kWh-110kW-2h South Africa datasheet | Manufacturer technical specification PDF · Preliminary South Africa-specific document.
Request a project quotation
Tell Solar Deity about your ST225kWh-110kW-2h project. The button opens our C&I enquiry form, where you can submit your requirements for a customized proposal.
Request a Project Quotation